mixture

Refinery fuel gas

Non-condensable refinery gas of crude distillation and conversion units: hydrogen, methane, ethane, some C3, and ethylene from cracking units, with H2S before amine treating; burnt in the refinery's heaters (refinery-distillation-1 overhead gas, fcc-1 dry gas, hydrocracking-1 C1-C2 gas). Composition by unit and site. No composition recorded yet: one goes in only with its source (docs/registry.md, Fuel mixtures).

Show in the process graph →

Made by

Used by

No process in the Atlas uses this yet.

When a process with this chemical is added to the library, it appears here.

Routes compared

All 4 ways to make Refinery fuel gas, with filters →

Not comparable as they standSystem boundary: differs; Data quality (TfS DQR): not stated by every route; Reference product (grade, state): not stated by every route. The rows say which route each warning concerns.

Per 1 kg of Refinery fuel gas: inventory from each route's LCI dataset, unallocated; footprints per the functional unit of their own LCA.

RouteTier, design maturity, review statusGeography, yearEnergyFeedstocksKey emissionsFootprintComparability
Catalytic reforming of naphtha with continuous catalyst regeneration (CCR)low-pressure (3.5 to 10 bar) moving-bed reforming over Pt-Sn/alumina with continuous catalyst regeneration; semi-regenerative and cyclic units are not modelledTier 1 (sourced conceptual)Design maturity: Concept (research)Not independently reviewedDataset review: unreviewedRER, 2010a co-product of a multi-output dataset (product:reformate, product:hydrogen, product:lpg besides it): its share needs the allocation of the LCI database buildno footprint
  • Reference product (grade, state): states no product
  • System boundary: boundary is gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside; the routes state gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside, gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside, gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it, gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside
  • Data quality (TfS DQR): states no data quality rating (TfS DQR)
Fluid catalytic cracking of vacuum gas oil (full-combustion regenerator)fluid catalytic cracking on zeolite catalyst, single-stage regenerator in full combustion (typical for vacuum distillate feeds, BREF section 2.5); residue cracking (RCC), partial combustion and propylene-maximising variants are not modelledTier 1 (sourced conceptual)Design maturity: Concept (research)Not independently reviewedDataset review: unreviewedGLO, 2010a co-product of a multi-output dataset (product:gasoline, product:lpg, product:light-cycle-oil, product:heavy-cycle-oil besides it): its share needs the allocation of the LCI database buildno footprint
  • Reference product (grade, state): states no product
  • System boundary: boundary is gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it; the routes state gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside, gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside, gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it, gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside
  • Data quality (TfS DQR): states no data quality rating (TfS DQR)
Hydrocracking of vacuum gas oil, single-stage recyclehigh-pressure fixed-bed hydrocracking (100 to 200 barg, 340 to 425 degC, REF BREF Table 2.9), single-stage with recycle of the unconverted oil; once-through, two-stage, mild and residue hydrocracking are not modelledTier 1 (sourced conceptual)Design maturity: Concept (research)Not independently reviewedDataset review: unreviewedRER, 1999a co-product of a multi-output dataset (product:hydrocracked-products, product:unconverted-oil besides it): its share needs the allocation of the LCI database buildno footprint
  • Reference product (grade, state): states no product
  • System boundary: boundary is gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside; the routes state gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside, gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside, gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it, gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside
  • Data quality (TfS DQR): states no data quality rating (TfS DQR)
Crude oil distillation, atmospheric and vacuum (crude and high vacuum units)atmospheric crude distillation at 0.5 to 1 barg with steam stripping (REF BREF 2.19); one crude assayTier 1 (sourced conceptual)Design maturity: Concept (research)Not independently reviewedDataset review: unreviewedRER, 2001a co-product of a multi-output dataset (product:lpg, product:naphtha, product:kerosene, product:gas-oil, product:atmospheric-residue besides it): its share needs the allocation of the LCI database buildno footprint
  • Reference product (grade, state): states no product
  • System boundary: boundary is gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside; the routes state gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside, gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside, gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it, gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside
  • Data quality (TfS DQR): states no data quality rating (TfS DQR)
How comparability is checked
Allocation
same (same allocation method: energy)
Background data (impacts)
not applicable (same background data and boundary behind the impact numbers (only routes with a footprint))
System boundary
differs (same system boundary of the inventory (the dataset's boundary): gate-to-gate: charge heater and interheaters, three to four moving-bed reactors, continuous regenerator, separators, recontacting and debutaniser; naphtha hydrotreating upstream is not included; fuel and power from outside, gate-to-gate: feed heater, reactors, HP and LP separators, fractionation; hydrogen, fuel and power from outside; amine treating, sulfur recovery and sour water stripping outside, gate-to-gate: feed preheat, riser reactor, catalyst stripper, regenerator with waste heat or CO boiler, main fractionator, wet gas compressor and gas plant; steam, power and fuel from outside; flue-gas abatement of the regenerator included only as far as the BREF's emission data include it, gate-to-gate: preheat furnace, atmospheric column, side strippers, overhead condensing; desalting, naphtha stabilisation and sour water stripping are outside; steam and power from outside)
Data quality (TfS DQR)
not stated by every route (data quality: every route states a TfS DQR, none more than 1 above the best)
Functional unit
same (same functional unit (amount and unit of the reference product): 1 kg)
Reference product (grade, state)
not stated by every route (same reference product: registry grade and state)
System model
same (same system model (docs/system-model.md): cutoff)

ISO 14044 requires a critical review (by a panel of interested parties, ISO/TS 14071) of a comparative assertion intended to be disclosed to the public. These routes are listed side by side for screening; a statement that one is better than another needs that review. None of these routes has had such a review.