MP steam export (4600 kPa(a), 673 K)
Activity Ammonia from natural gas (1500 t/d, steam reforming with air-fed secondary reformer, Haber-Bosch loop), NL: the inventory of 1 kilogram of its reference product, attributional, cut-off.
What it is
Unallocated foreground LCI of Ammonia from natural gas, 1500 t/d (steam reforming, air-fed secondary reformer, Haber-Bosch loop), case design, derived from the flowsheet by cheme assess lca.
- Reference product
- 1 kilogram of MP steam export (4600 kPa(a), 673 K) (46 bar(a), 400 degC, 100 % H2O (mole))
- Chemical
- steam
- CAS
- not available
- Code
- ammonia-1:ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop:product:STEAM
- Dataset
- ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop version 0.1.0 · UUID 13401756-15c9-5082-831d-0551355dbc05
- Activity UUID
- not available (the library assigns none; use the code)
- Database
- cheme-as-code-atlas-preview-c3ab348 (version preview-c3ab348)
- Process
- Ammonia from natural gas (1500 t/d, steam reforming with air-fed secondary reformer, Haber-Bosch loop)
- Geography
- NL · background inputs with a site rule link at the user's site location (default DE)
- Time period
- 2026 · valid until 2031
- Technology
- steam methane reforming with air-blown secondary reformer, HT/LT shift, aMDEA CO2 removal (CO2 vented), methanation, 150 bar Haber-Bosch loop with purge recovery; electric drives, MP steam export · level current
- Boundary
- gate-to-gate foreground of the plant
- Production volume
- 499,774,400 kg/a (product:NH3 per hour x operation.hours_per_year (8000 h/a))
- Classification
- ISIC Rev.4 2012 (taxonomy/families.yaml (ISIC Rev.4) of the process's families)
- System model
- attributional, cut-off (docs/system-model.md, methodology 1.1.0)
- Allocation
- exergy, 6 % of the dataset to this product (rule deviation, from study)D-021: no co-product price is recorded, so the WBCSD price ratio is unknown, and mass allocation would charge 0.88 kg of steam per kg NH3 with 47 % of the gas, feed and emissions of an ammonia plant. Exergy is the physical relationship between the products.
- Rights
- CC-BY-4.0: the ChemE-as-Code process library's own concept design (LICENSE-DATA)
Exchanges per 1 kilogram of MP steam export (4600 kPa(a), 673 K)
As exported: allocated and scaled to the reference product. Provenance: 2 given, 10 assumed. Pedigree scores (1 best, 5 worst): reliability, completeness, temporal correlation, geographical correlation, further technological correlation.
| Input | Amount | Unit | Provenance | Pedigree | Linked to |
|---|---|---|---|---|---|
| Natural gas (feed and fuel) feed:NG flowsheet S1 (S3 process feed + S2 furnace fuel) From stream S1 | 0.03353 | kilogram | given | 3 4 1 1 3 | Atlas: natural gas, per kg, as methane (Atlas unit proxy) (natural gas, by mass, GLO) |
| Demineralised water make-up feed:DMW flowsheet S70 (steam system) + S26 (CO2 removal make-up) | 0.1033 | kilogram | given | 3 4 1 1 3 | market for water, deionised (water, deionised, RoW) in your background (default ecoinvent-3.11-cutoff) |
| Electric power feed:POWER flowsheet Q1, Q11, Q12, Q17, Q20, Q22, Q27, Q31 (all drives electric, D-016) electricity | 0.03459 | kilowatt hour | assumed | 4 4 1 1 3 | market for electricity, medium voltage (electricity, medium voltage, DE, site location) in your background (default ecoinvent-3.11-cutoff) |
| Boiler blowdown product:BD flowsheet S69, 2 % of steam raised (D-015) From stream S69 | 0.002948 | kilogram | assumed | 4 4 1 1 3 | Atlas (plant): wastewater to treatment, per kg (Atlas unit proxy) (wastewater, by mass, GLO) compatible: grade the input names wastewater only; wastewater (Wastewater treated) is taken; unit kilogram; system model cutoff (one database); allocation mass (single-output); boundary plant gate of a site utility: no utility market yet (docs/markets.md) |
| Cooling water return product:CW flowsheet Q2, Q16, Q18, Q19, Q21, Q24, Q28 cold, 25 degC | 0.1284 | kilowatt hour | assumed | 4 4 1 1 3 | Atlas (plant): cooling water service, per kWh heat rejected (Atlas screening proxy) (heat rejected to cooling water, GLO) compatible: grade the input names cooling-water only; cooling-water (Heat rejected to cooling water, 25/35 degC) is taken; unit kilowatt hour; carrier cold, 25 degC from cold, 25 degC; system model cutoff (one database); allocation mass (single-output); boundary plant gate of a site utility: no utility market yet (docs/markets.md) |
Elementary flows
| Flow | Direction | Compartment | Amount | Unit | Provenance | Pedigree |
|---|---|---|---|---|---|---|
| Ethane 8e30c990-5ed4-4f94-9d0e-2f5e4ff1a1f9 | emission | air | 0 | kilogram | assumed | 4 4 1 1 3 |
| Propane 3a6c936c-0276-4f11-9d98-1bd011387a6e | emission | air | 0 | kilogram | assumed | 4 4 1 1 3 |
| Methane, fossil 70ef743b-3ed5-4a6d-b192-fb6d62378555 | emission | air / non-urban air or from high stacks | 4.051e-11 | kilogram | assumed | 4 4 1 1 3 |
| Carbon monoxide, fossil 099b36ab-4c03-4587-87f4-2f81e337afb8 | emission | air / non-urban air or from high stacks | 1.733e-9 | kilogram | assumed | 4 4 1 1 3 |
| Carbon dioxide, fossil aa7cac3a-3625-41d4-bc54-33e2cf11ec46 | emission | air / non-urban air or from high stacks | 0.09156 | kilogram | assumed | 4 4 1 1 3 |
| Hydrogen no biosphere3 UUID: linked by name and compartment | emission | air | 5.485e-8 | kilogram | assumed | 4 4 1 1 3 |
| Ammonia 0f440cc0-0f74-446d-99d6-8ff0e97a2444 | emission | air / non-urban air or from high stacks | 0 | kilogram | assumed | 4 4 1 1 3 |
The streams are the plant's own flows: an amount here is allocated and per 1 kilogram of MP steam export (4600 kPa(a), 673 K), so it differs from the stream's flow, and it can sum several streams.
Where these numbers come from: each exchange names its source above; the dataset is processes/ammonia-1/lca/dataset.yaml in library version c3ab348.
Used by
No other activity of this database links to it.
How good it is
- Review
- Not reviewed: no LCI review record yet
- Data quality
- DQR 1.67 · PEF-style DQR 2.25TeR 3 · GeR 1 · TiR 1 · P 4 · C 4 · weakest TeR · primary data 0 %
- Mass and carbon closure
- Assessed (lca/manifest.json balance, tolerance 5 %: design maturity concept (sourced screening))
- lci-carbon-origin: closed
- lci-element-balance: closed
- lci-mass-balance: closed
- Change report
- Not available: this build has no change report against an earlier release.
KPI benchmark positions
| KPI | Value | Reference range | Position |
|---|---|---|---|
| Total direct CO2 emitted per t of ammonia (process plus combustion) | – t/t | 1.8 to 1.8 t/t | not evaluated |
| Process CO2 generated per t of ammonia (excluding combustion flue gas) | – t/t | 1.15 to 1.4 t/t | not evaluated |
How to use it
Downloads
- cheme-as-code-atlas-preview-c3ab348.xlsx · bw2io ExcelImporter workbook (bw2io 0.9 Excel layout) · the whole databasecode ammonia-1:ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop:product:STEAM
- cheme-as-code-atlas-preview-c3ab348-olca-jsonld.zip · openLCA JSON-LD (olca-schema) (2) · the whole databaseprocess 13401756-15c9-5082-831d-0551355dbc05 (processes/13401756-15c9-5082-831d-0551355dbc05.json) · the dataset's unallocated multi-output process; this product's allocation factor is in it
- cheme-as-code-atlas-preview-c3ab348-multifunctional.json · Brightway 2.5 multifunctional database (JSON, for the multifunctional package) (cheme-as-code/lci-multifunctional/v1) · the whole databasecode ammonia-1:ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop · the dataset unallocated, with all its products; this product is its desired_code
- cheme_as_code_lci-0.1.0-py3-none-any.whl · the installer
A file with this activity alone is not available: each file above is the whole database, and the line under it says how to find this activity there.
import bw2data as bd
from cheme_as_code_lci import install
bd.projects.set_current("my-project") # holds your licensed background + biosphere3
install("cheme-as-code-atlas-preview-c3ab348.xlsx", background="ecoinvent-3.11-cutoff", location="DE")
activity = bd.get_activity(("cheme-as-code-atlas-preview-c3ab348", "ammonia-1:ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop:product:STEAM"))While any exchange of the database has no mapping, install() writes nothing and only lists the unlinked exchanges. So the last line finds no activity until the gaps are mapped: the download section gives the ways to use the database now.
How to cite
MP steam export (4600 kPa(a), 673 K), from Ammonia from natural gas (1500 t/d, steam reforming with air-fed secondary reformer, Haber-Bosch loop) (dataset ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop 0.1.0), ChemE-as-Code Process Atlas LCI database preview-c3ab348, activity ammonia-1:ammonia-from-natural-gas-1500-t-d-steam-reforming-air-fed-secondary-reformer-haber-bosch-loop:product:STEAM. Cite the Process Atlas paper (in preparation, 2026), by Artur M. Schweidtmann and Jana M. Weber, and the ChemE-as-Code Process Atlas LCI database version preview-c3ab348.
DOI: none yet (the Process Atlas paper is in preparation)
For the data, cite the Process Atlas paper; for the platform that builds and checks it, the ChemE-as-Code paper.
Schweidtmann, A. M. & Weber, J. M. (2026, in preparation). Process Atlas: an open, git-native, reproducible library and life cycle inventory of chemical processes (working title).
BibTeX
@unpublished{schweidtmann_process_atlas,
author = {Schweidtmann, Artur M. and Weber, Jana M.},
title = {{Process Atlas: an open, git-native, reproducible library and life cycle inventory of chemical processes (working title)}},
year = {2026},
url = {https://atlas.cheme-as-code.org},
note = {in preparation}
}Schweidtmann, A. M. (2026, in preparation). ChemE-as-Code: An Open-Source Platform for AI-Accelerated Chemical Process Engineering (working title).
BibTeX
@unpublished{schweidtmann_cheme_as_code,
author = {Schweidtmann, Artur M.},
title = {{ChemE-as-Code: An Open-Source Platform for AI-Accelerated Chemical Process Engineering (working title)}},
year = {2026},
url = {https://cheme-as-code.org},
note = {in preparation}
}